PerkinElmer® Lumina Single-Element Hollow Cathode Lamps, 2 in. (50 mm), Zirconium (Zr)

Series N30501XX Lumina 2 in. (50 mm) diameter single-element lamps are designed to be used with PerkinElmer® PinAAcle and AAnalyst Atomic Absorption spectrometer series of instruments.
Single Element Lumina Hollow Cathode Lamp (HCL) for the detection of elemental Zirconium (Zr). Please note that this element requires the use of a nitrous oxide-acetylene flame. Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer® spectrometers to assure compatibility and the highest performance. We offer a wide range of single-element and multi-element HCLs, which are ideal for determining most elements by atomic absorption spectroscopy. To prolong the life of a Lumina Hollow Cathode Lamp (HCL), we produce lamps with larger internal volume so that a greater supply of fill gas at optimum pressure is available. The larger the lamp, the greater the inert gas volume - and the longer the lamp lifetime. Note: Lumina Hollow Cathode Lamps may also be used with all earlier AA spectrometers that do not have automatic code reading capability by using an appropriate adapter cable.


Image(s) are representative of the product group and not necessarily the individual product.
Read More
Series N30501XX Lumina 2 in. (50 mm) diameter single-element lamps are designed to be used with PerkinElmer® PinAAcle and AAnalyst Atomic Absorption spectrometer series of instruments.
Single Element Lumina Hollow Cathode Lamp (HCL) for the detection of elemental Zirconium (Zr). Please note that this element requires the use of a nitrous oxide-acetylene flame. Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer® spectrometers to assure compatibility and the highest performance. We offer a wide range of single-element and multi-element HCLs, which are ideal for determining most elements by atomic absorption spectroscopy. To prolong the life of a Lumina Hollow Cathode Lamp (HCL), we produce lamps with larger internal volume so that a greater supply of fill gas at optimum pressure is available. The larger the lamp, the greater the inert gas volume - and the longer the lamp lifetime. Note: Lumina Hollow Cathode Lamps may also be used with all earlier AA spectrometers that do not have automatic code reading capability by using an appropriate adapter cable.


Image(s) are representative of the product group and not necessarily the individual product.

Certificates of Analysis

This service is currently unavailable!

2023