PerkinElmer® High Sensitivity Nebulizers

This High Sensitivity Nebulizer Assembly is for use with AAnalyst® 100/300/200/400/700/800 and earlier AA series instruments. It provides maximum sensitivity, precision and freedom from analytical interferences.

A complete High-Sensitivity plastic body nebulizer featuring Kalrez o-rings and Platinum/Iridium needle (Cat. No. 290-10646) or Tantalum needle (Cat. No. 290-10853). The body is fabricated of inert plastic materials for maximum performance and corrosion resistance. This high-sensitivity nebulizer with Pt/Ir needle is for most solutions, but not for precious metal samples containing aqua regia.

Each assembly includes:
• Impact Bead, Qty. 1 (replacements available, see Cat. No. 290-10241)
• Solvent resistant O-Ring for Nebulizer Body, Qty. 1 (replacements available, see Cat. No. 290-13634)
• Nebulizer Body, Qty. 1
• Spring, Qty. 1
• Solvent Resistant O-Ring for Capillary Assembly, Qty. 1 (replacements available, see Cat. No. 290-14096)
• Pt/Ir Capillary Assembly with O-Ring, Qty. 1
• Locking Ring, Qty. 1
• Fine Adjustment Nut, Qty. 1

Compatible With:
• PerkinElmer AAnalyst® 200/400/700/800 and Model 5100PC/5000/3300/3110/3100 AA instruments.

Note: The AAnalyst® 800 requires end cap assembly
• Cat. No. 290-1174: End Cap Assembly for instruments shipped before Fall 1999. Required when using High Sensitivity Nebulizer (Cat. No. 290-10646 and 290-10853).

Image(s) are representative of the product group and not necessarily the individual product.
Read More
This High Sensitivity Nebulizer Assembly is for use with AAnalyst® 100/300/200/400/700/800 and earlier AA series instruments. It provides maximum sensitivity, precision and freedom from analytical interferences.

A complete High-Sensitivity plastic body nebulizer featuring Kalrez o-rings and Platinum/Iridium needle (Cat. No. 290-10646) or Tantalum needle (Cat. No. 290-10853). The body is fabricated of inert plastic materials for maximum performance and corrosion resistance. This high-sensitivity nebulizer with Pt/Ir needle is for most solutions, but not for precious metal samples containing aqua regia.

Each assembly includes:
• Impact Bead, Qty. 1 (replacements available, see Cat. No. 290-10241)
• Solvent resistant O-Ring for Nebulizer Body, Qty. 1 (replacements available, see Cat. No. 290-13634)
• Nebulizer Body, Qty. 1
• Spring, Qty. 1
• Solvent Resistant O-Ring for Capillary Assembly, Qty. 1 (replacements available, see Cat. No. 290-14096)
• Pt/Ir Capillary Assembly with O-Ring, Qty. 1
• Locking Ring, Qty. 1
• Fine Adjustment Nut, Qty. 1

Compatible With:
• PerkinElmer AAnalyst® 200/400/700/800 and Model 5100PC/5000/3300/3110/3100 AA instruments.

Note: The AAnalyst® 800 requires end cap assembly
• Cat. No. 290-1174: End Cap Assembly for instruments shipped before Fall 1999. Required when using High Sensitivity Nebulizer (Cat. No. 290-10646 and 290-10853).

Image(s) are representative of the product group and not necessarily the individual product.