Thermo Scientific Orion Star A211 pH Benchtop Meter with Stand

Includes:
• Star A211 pH Meter
• Electrode Stand
• 100-240V Universal Power Adapter, Cat. No. 246-47902 (1010003)
• Computer Cable

Specifications
• Alarm Output: High/low limit alarm, calibration due alarm
• Battery Life: 800 hr.
• Certifications/Compliance: CE, TUV 3-1, FCC Class A
• Channels: 1
• Accuracy (mV): +/-0.2 mV or +/-0.05% of reading whichever is greater
• Accuracy (pH): +/-0.002 pH
• Accuracy (Temp.): +/-0.1°C
• Backlight Option: Yes, selectable
• Calibration: pH with calibration editing option, relative mV (RmV), ORP and temp.
• Calibration Points: 1 to 5
• Data Management Details: Transfer single, range or all data points to printer or computer
• Data Points: 2000 with Date and Time Stamp
• Display Type: LCD (Graphic with Backlight)
• Log Function Type: Automatic data logging with Auto-Read and Timed measure modes
• Measurement Modes: pH, mV, relative mV (RmV) or ORP with temperature
• Outputs: USB, RS-232
• Range (mV): +/-2000 mV
• Range (pH): -2 to 20
• Resolution (pH): 0.1, 0.01, 0.001
• Temp. Range: -5 to +105°C
• Inputs: BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
• IP Rating: IP-54
• Isopotential Point: 7.000pH
• Keypad: Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
• Languages: Multi
• Memory: Non-volatile memory preserves data log, calibration log and meter settings
• Methods: 10 per channel with password protection
• Power Supply: Universal AC adapter (included) or 4 AA batteries (sold separately)
• Probe Type: pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirre
Read More
Includes:
• Star A211 pH Meter
• Electrode Stand
• 100-240V Universal Power Adapter, Cat. No. 246-47902 (1010003)
• Computer Cable

Specifications
• Alarm Output: High/low limit alarm, calibration due alarm
• Battery Life: 800 hr.
• Certifications/Compliance: CE, TUV 3-1, FCC Class A
• Channels: 1
• Accuracy (mV): +/-0.2 mV or +/-0.05% of reading whichever is greater
• Accuracy (pH): +/-0.002 pH
• Accuracy (Temp.): +/-0.1°C
• Backlight Option: Yes, selectable
• Calibration: pH with calibration editing option, relative mV (RmV), ORP and temp.
• Calibration Points: 1 to 5
• Data Management Details: Transfer single, range or all data points to printer or computer
• Data Points: 2000 with Date and Time Stamp
• Display Type: LCD (Graphic with Backlight)
• Log Function Type: Automatic data logging with Auto-Read and Timed measure modes
• Measurement Modes: pH, mV, relative mV (RmV) or ORP with temperature
• Outputs: USB, RS-232
• Range (mV): +/-2000 mV
• Range (pH): -2 to 20
• Resolution (pH): 0.1, 0.01, 0.001
• Temp. Range: -5 to +105°C
• Inputs: BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
• IP Rating: IP-54
• Isopotential Point: 7.000pH
• Keypad: Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
• Languages: Multi
• Memory: Non-volatile memory preserves data log, calibration log and meter settings
• Methods: 10 per channel with password protection
• Power Supply: Universal AC adapter (included) or 4 AA batteries (sold separately)
• Probe Type: pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirre

Certificates of Analysis