Labconco® 4 ft. Protector XL I-S Benchtop Laboratory Hoods

Protector XL I-S Benchtop Laboratory Hoods are general chemistry hoods that offer superior design flexibility. They are available in widths from 3 to 8 feet and two depths to meet a variety of installation and application requirements.

Designed for use with Intelli-Sense Multi-Speed Blowers, Protector XL I-S Benchtop Hoods feature integrated sash position blower controls. As the sash is raised or lowered, sensors alert the blower to change speeds to maintain a safe face velocity. That face velocity is displayed on the factory-installed Guardian Digital Airflow Monitor for users' peace of mind.

These hoods are suitable for providing personal protection needed for general chemistry applications involving fumes and vapors. They meet the SEFA-1 standard of a low velocity, high performance hood and may be safely operated as low as 60 fpm.

Specifications
• Nominal Width: 4 ft.
• Blower Requirements: Remote blower required
• Conformance: ADA, ANSI Z9.5, ASHRAE 110, ASTM E84, CAN/CSA C22.2, CFR 29, NFPA 45, SEFA 1, UL 1805, UL 61010
• Dimensions (W x D x H): 48 x 37.7 x 59 in.
• Enclosure Height: 59 in.
• Exterior Depth: 37.7 in.
• Interior Depth: 30 in.
• Lighting: LED
• Style: Benchtop

Image(s) are representative of the product group and not necessarily the individual product.
Read More
Protector XL I-S Benchtop Laboratory Hoods are general chemistry hoods that offer superior design flexibility. They are available in widths from 3 to 8 feet and two depths to meet a variety of installation and application requirements.

Designed for use with Intelli-Sense Multi-Speed Blowers, Protector XL I-S Benchtop Hoods feature integrated sash position blower controls. As the sash is raised or lowered, sensors alert the blower to change speeds to maintain a safe face velocity. That face velocity is displayed on the factory-installed Guardian Digital Airflow Monitor for users' peace of mind.

These hoods are suitable for providing personal protection needed for general chemistry applications involving fumes and vapors. They meet the SEFA-1 standard of a low velocity, high performance hood and may be safely operated as low as 60 fpm.

Specifications
• Nominal Width: 4 ft.
• Blower Requirements: Remote blower required
• Conformance: ADA, ANSI Z9.5, ASHRAE 110, ASTM E84, CAN/CSA C22.2, CFR 29, NFPA 45, SEFA 1, UL 1805, UL 61010
• Dimensions (W x D x H): 48 x 37.7 x 59 in.
• Enclosure Height: 59 in.
• Exterior Depth: 37.7 in.
• Interior Depth: 30 in.
• Lighting: LED
• Style: Benchtop

Image(s) are representative of the product group and not necessarily the individual product.

Certificates of Analysis

This service is currently unavailable!

2023