Titan3<sup>®</sup> Regenerated Cellulose Syringe Filters

Titan3® Regenerated Cellulose Syringe Filters

Regenerated cellulose syringe filters are ideally suited for almost any laboratory procedure, from HPLC sample preparation to dissolution sample testing. Regenerated cellulose possesses superior chemical resistance in either aqueous or organic-based sample environments. Its extremely low biological-based binding coefficient is ideally suited for maximum sample recoveries of biological-based assays. Regenerated cellulose contains no binders, surfactants or wetting agents to assure minimal extractables in analytical procedures.

• Hydrophilic membrane provides excellent flow rates and extremely low binding coefficients
• Superior choice for biological assays, gel capsule dissolution testing, protein sample matrixes
• Compatible with a wide range of aqueous and organic-based sample environments
• Recommended for reverse phase and normal phase HPLC

Titan3 Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles. With a robust design that includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required.

• Housings are manufactured from solvent-resistant, low-extractable polypropylene resins
• Color coding makes it easy to select the correct membrane and pore size
• Packed in reusable rigid transparent color-coded containers
• Enhanced luer lock inlet prevents leakage; outlet fitting is a standard size male luer-slip fitting for ease of filtrate collection

Specifications
• Membrane: HPLC certified regenerated cellulose
• Protein binding: <5 g/cm2
• Porosities: 0.20 m and 0.45 m
• Autoclave: Sterilize by dry heat at 121°C for 15 minutes
• Pre-filter (if fitted) GMF 1 m

Applications:
• HPLC and organic solvent sample preparation and clean up
• Dissolution sample analysis, especially high-binding tablets or capsules
• Protein-based samples with high non-specific binding
• Sample analysis which require maximum recoveries
• Analysis requiring low non-specific binding over a wide pH range

Chemical Incompatibilities:
• Sulfuric acid, hydrochloric acid, phosphoric acid or nitric acid >25%, DMF, phenol

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
885-10115-PK 4 mm Titan3 0.2 um Regenerated Cellulose Syringe Filters, Granite - 100 ea

Specifications

52204-RC $136.80 PK
885-10118-PK 4 mm Titan3 0.45 um Regenerated Cellulose Syringe Filters, Light Brown - 100 ea

Specifications

54504-RC $138.95 PK
885-10121-PK 17 mm Titan3 0.2 um Regenerated Cellulose Syringe Filters, Granite - 200 ea

Specifications

52213-RC $527.10 PK
885-10124-PK 17 mm Titan3 0.45 um Regenerated Cellulose Syringe Filters, Light Brown - 200 ea

Specifications

54513-RC $470.90 PK
475-69712-CS 17 mm Titan3 0.45 um Regenerated Cellulose Syringe Filters, Light Brown - 5000 ea

Specifications

54513-RCBX $20822.40 CS
885-10127-PK 30 mm Titan3 0.2 um Regenerated Cellulose Syringe Filters, Granite - 100 ea

Specifications

52225-RC $393.50 PK
885-10130-PK 30 mm Titan3 0.45 um Regenerated Cellulose Syringe Filters, Light Brown - 100 ea

Specifications

54525-RC $373.35 PK
475-69730-CS 30 mm Titan3 0.45 um Regenerated Cellulose Syringe Filters, Light Brown - 500 ea

Specifications

54525-RCC $1608.95 CS

Description Back to Top

Regenerated cellulose syringe filters are ideally suited for almost any laboratory procedure, from HPLC sample preparation to dissolution sample testing. Regenerated cellulose possesses superior chemical resistance in either aqueous or organic-based sample environments. Its extremely low biological-based binding coefficient is ideally suited for maximum sample recoveries of biological-based assays. Regenerated cellulose contains no binders, surfactants or wetting agents to assure minimal extractables in analytical procedures.

• Hydrophilic membrane provides excellent flow rates and extremely low binding coefficients
• Superior choice for biological assays, gel capsule dissolution testing, protein sample matrixes
• Compatible with a wide range of aqueous and organic-based sample environments
• Recommended for reverse phase and normal phase HPLC

Titan3 Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles. With a robust design that includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required.

• Housings are manufactured from solvent-resistant, low-extractable polypropylene resins
• Color coding makes it easy to select the correct membrane and pore size
• Packed in reusable rigid transparent color-coded containers
• Enhanced luer lock inlet prevents leakage; outlet fitting is a standard size male luer-slip fitting for ease of filtrate collection

Specifications
• Membrane: HPLC certified regenerated cellulose
• Protein binding: <5 g/cm2
• Porosities: 0.20 m and 0.45 m
• Autoclave: Sterilize by dry heat at 121°C for 15 minutes
• Pre-filter (if fitted) GMF 1 m

Applications:
• HPLC and organic solvent sample preparation and clean up
• Dissolution sample analysis, especially high-binding tablets or capsules
• Protein-based samples with high non-specific binding
• Sample analysis which require maximum recoveries
• Analysis requiring low non-specific binding over a wide pH range

Chemical Incompatibilities:
• Sulfuric acid, hydrochloric acid, phosphoric acid or nitric acid >25%, DMF, phenol

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
326189 has a rating of 4.9 stars based on 10 reviews.