We manufacture and distribute fine chemicals and laboratory
products - with quality and delivery you can count on every time.

Corner
Titan3<sup>®</sup> PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified

Titan3® PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified

PES syringe filters provide precise results in sensitive analysis of ionic analytes. This hydrophilic polymer has excellent cleanliness and is compatible with a wide range of solvents. It is the membrane of choice for ion chromatography applications.

• Certified for low-level IC interference by ICP analysis
• Hydrophilic membrane provides excellent flow rates and low binding coefficients
• Low affinity for binding drugs, ideal for dissolution testing procedures

Titan3 Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles. With a robust design that includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required.

• Low extractable membranes and housings ensure that no filter-borne contaminants are added to your sample
• Performance-tested under actual HPLC conditions
• Housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices
• Color coding makes it easy to select the correct membrane and pore size
• Packed in reusable rigid transparent color-coded containers
• Enhanced luer lock inlet prevents leakage; outlet fitting is a standard size male luer-slip fitting for ease of filtrate collection

Specifications
• Membrane: ICP Certified PES (PolyEtherSulfone)
• Max. operating temperature: 100°C
• Housing: medical grade, virgin polypropylene
• Pre-filter: binder-free glass microfiber pre-filter (0.20 m only)
• Porosities: 0.20 m and 0.45 m
• Autoclave: Sterilize by dry heat at 121°C for 15 minutes

Applications:
• IC sample preparation and analysis
• Dissolution testing

Chemical Incompatibilities:
• Protein-based samples in aqueous solutions
• Concentrated acids, chloromethane, chloroform, hexane, acetone, MEK, THF, DMSO

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
885-10133-PK 17 mm Titan3 0.2 um PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified, Dark Gray - 200 ea

Specifications

42213-PS $330.35 PK
885-10136-PK 17 mm Titan3 0.45 um PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified, Orange/Yellow - 200 ea

Specifications

44513-PS $330.35 PK
885-10139-PK 30 mm Titan3 0.2 um PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified, Dark Gray - 100 ea

Specifications

42225-PS $239.90 PK
885-10142-PK 30 mm Titan3 0.45 um PES (Polyethersulfone) Syringe Filters - Ion Chromatography (IC) Certified, Orange/Yellow - 100 ea

Specifications

44525-PS $237.50 PK

Description Back to Top

PES syringe filters provide precise results in sensitive analysis of ionic analytes. This hydrophilic polymer has excellent cleanliness and is compatible with a wide range of solvents. It is the membrane of choice for ion chromatography applications.

• Certified for low-level IC interference by ICP analysis
• Hydrophilic membrane provides excellent flow rates and low binding coefficients
• Low affinity for binding drugs, ideal for dissolution testing procedures

Titan3 Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles. With a robust design that includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required.

• Low extractable membranes and housings ensure that no filter-borne contaminants are added to your sample
• Performance-tested under actual HPLC conditions
• Housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices
• Color coding makes it easy to select the correct membrane and pore size
• Packed in reusable rigid transparent color-coded containers
• Enhanced luer lock inlet prevents leakage; outlet fitting is a standard size male luer-slip fitting for ease of filtrate collection

Specifications
• Membrane: ICP Certified PES (PolyEtherSulfone)
• Max. operating temperature: 100°C
• Housing: medical grade, virgin polypropylene
• Pre-filter: binder-free glass microfiber pre-filter (0.20 m only)
• Porosities: 0.20 m and 0.45 m
• Autoclave: Sterilize by dry heat at 121°C for 15 minutes

Applications:
• IC sample preparation and analysis
• Dissolution testing

Chemical Incompatibilities:
• Protein-based samples in aqueous solutions
• Concentrated acids, chloromethane, chloroform, hexane, acetone, MEK, THF, DMSO

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
326187 has a rating of 4.9 stars based on 10 reviews.