We manufacture and distribute fine chemicals and laboratory
products - with quality and delivery you can count on every time.

Corner
Cameo<sup>®</sup> 30 mm Syringe Filters, Polypropylene with GF Prefilter

Cameo® 30 mm Syringe Filters, Polypropylene with GF Prefilter

Polypropylene membrane filters are composed of pure polypropylene with absolute pore size ratings. These filters offer broad chemical compatibility allowing its use with aqueous and organic solvents samples. The polypropylene filter has extremely low extractable levels designed to provide accurate, consistent analysis results for sensitive ion chromatography applications while prolonging column life.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

30 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Polypropylene with Glass Fiber prefilter
• Autoclavable: Yes
• Filtration area: 4.8 cm2
• Housing diameter: 33 mm
• Membrane diameter: 30 mm
• Holdup volume: < 60 mL
• Sample volume: < 120 mL without prefilter
• Inlet/outlet: Female luer lock/Male luer slip

Applications:
• HPLC sample preparation
• Dissolution testing
• Content uniformity
• Environmental samples
• Composite assays
• Food analysis
• Biofuel analysis

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
880-26779 Cameo PP (PG) Glass Fiber Prefilter Syringe Filter - 200 ea

1224176 $620.00 PK
880-26803 Cameo PP (PG) Glass Fiber Prefilter Syringe Filter - 200 ea

1224314 $647.60 PK
880-26773 Cameo PP (PG) Glass Fiber Prefilter Syringe Filter - 50 ea

1224175 $178.45 PK
880-26797 Cameo PP (PG) Glass Fiber Prefilter Syringe Filter - 50 ea

1224313 $178.45 PK
889-80052-PK CAMEO Syringe Filter,Glass Fiber/PP, 0.22 um, 30 mm dia. - 500 ea

1224177 $1446.55 PK
889-80055-PK CAMEO Syringe Filter,Glass Fiber/PP, 0.45 um, 30 mm dia. - 500 ea

1224315 $1446.55 PK

Description Back to Top

Polypropylene membrane filters are composed of pure polypropylene with absolute pore size ratings. These filters offer broad chemical compatibility allowing its use with aqueous and organic solvents samples. The polypropylene filter has extremely low extractable levels designed to provide accurate, consistent analysis results for sensitive ion chromatography applications while prolonging column life.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

30 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Polypropylene with Glass Fiber prefilter
• Autoclavable: Yes
• Filtration area: 4.8 cm2
• Housing diameter: 33 mm
• Membrane diameter: 30 mm
• Holdup volume: < 60 mL
• Sample volume: < 120 mL without prefilter
• Inlet/outlet: Female luer lock/Male luer slip

Applications:
• HPLC sample preparation
• Dissolution testing
• Content uniformity
• Environmental samples
• Composite assays
• Food analysis
• Biofuel analysis

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
302820 has a rating of 4.9 stars based on 10 reviews.