We manufacture and distribute fine chemicals and laboratory
products - with quality and delivery you can count on every time.

Corner
Cameo<sup>®</sup> 30 mm Syringe Filters, Cellulose Acetate with GF Prefilter

Cameo® 30 mm Syringe Filters, Cellulose Acetate with GF Prefilter

Hydrophilic cellulose acetate membrane. Low protein binding (3.8 µg/cm2), ideal for protein, cell culture media and enzymes filtrations, tissue culture media sterilization, biological fluid filtration and other filtration applications where maximum recovery of proteins is critical. The 0.22 µm membrane is the filter of choice for sterile filtration of aqueous solutions such as nutrient media, buffers and sera. The 0.45 m membrane is a very convenient filter type for the reduction of particles and microorganisms in aqueous solutions such as nutrient media, buffers and sera. Enhanced recovery of fastidious gram positive organisms.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

30 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Cellulose Acetate with Glass Fiber prefilter
• Autoclavable: Yes
• Filtration area: 4.8 cm2
• Housing diameter: 33 mm
• Membrane diameter: 30 mm
• Holdup volume: < 60 mL
• Sample volume: < 120 mL without prefilter
• Inlet/outlet: Female luer lock/Male luer slip

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
880-26653 Cameo CA (AG) Glass Fiber Prefilter Syringe Filter, 0.22 um, 30 mm - 1000 ea

Specifications

1229466 $2185.15 PK
880-26656 Cameo CA (AG) Glass Fiber Prefilter Syringe Filter, 0.22 um, 30 mm - 50 ea

Specifications

1226942 $178.45 PK
889-80019-PK CAMEO Syringe Filter,Glass Fiber/Cellulose Acetate, 0.45 um, 30 mm dia. - 5000 ea

1270153 $10421.40 PK
889-80022-PK CAMEO Syringe Filter,Glass Fiber/Cellulose Acetate, 0.8 um, 30 mm dia. - 500 ea

1226950 $1385.00 PK

Description Back to Top

Hydrophilic cellulose acetate membrane. Low protein binding (3.8 µg/cm2), ideal for protein, cell culture media and enzymes filtrations, tissue culture media sterilization, biological fluid filtration and other filtration applications where maximum recovery of proteins is critical. The 0.22 µm membrane is the filter of choice for sterile filtration of aqueous solutions such as nutrient media, buffers and sera. The 0.45 m membrane is a very convenient filter type for the reduction of particles and microorganisms in aqueous solutions such as nutrient media, buffers and sera. Enhanced recovery of fastidious gram positive organisms.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

30 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Cellulose Acetate with Glass Fiber prefilter
• Autoclavable: Yes
• Filtration area: 4.8 cm2
• Housing diameter: 33 mm
• Membrane diameter: 30 mm
• Holdup volume: < 60 mL
• Sample volume: < 120 mL without prefilter
• Inlet/outlet: Female luer lock/Male luer slip

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
302824 has a rating of 4.9 stars based on 10 reviews.