We manufacture and distribute fine chemicals and laboratory
products - with quality and delivery you can count on every time.

Corner
Cameo<sup>®</sup> 17 mm Syringe Filters, Nylon with GF Prefilter

Cameo® 17 mm Syringe Filters, Nylon with GF Prefilter

Nylon membranes are naturally hydrophilic with a wide chemical compatibility range. Ideal for use in general filtration or medical assays. Featuring low extractables and lot-to-lot consistency. Ideal for use in general filtration and HLPC sample preparation of aqueous, solvent-based and organic solutions prior to chromatography or other instrument analyses; Excellent chemical compatibility with esters, bases, and alcohols; Biological sample preparation; High protein binding capacity: Immobilizes antigens, antibodies and other protein.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

17 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Nylon with Glass Fiber prefilter
• Autoclavable: Yes
• Prefilter: 1 micron binderless glass fiber
• Filtration area: 1.4 cm2
• Housing diameter: 22 mm
• Membrane diameter: 17 mm
• Holdup volume: < 15 mL
• Sample volume: < 18 mL
• Maximum operating temperature 82°C (180°F)
• Maximum operating pressure: 130 psi
• Inlet/outlet: Female luer lock / Male luer slip

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
880-26833 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 1000 ea

1229479 $1649.70 PK
880-26818 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 200 ea

1224767 $422.60 PK
880-26842 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 200 ea

1224774 $422.60 PK
880-26812 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 50 ea

1224766 $125.85 PK
880-26836 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 50 ea

1224773 $125.85 PK
880-26839 Cameo Nylon (RG) Glass Fiber Prefilter Syringe Filter - 500 ea

1224775 $966.85 PK
889-80025-PK CAMEO Syringe Filter,Glass Fiber/Nylon, 0.22 um, 17 mm dia. - 500 ea

1224768 $966.85 PK

Description Back to Top

Nylon membranes are naturally hydrophilic with a wide chemical compatibility range. Ideal for use in general filtration or medical assays. Featuring low extractables and lot-to-lot consistency. Ideal for use in general filtration and HLPC sample preparation of aqueous, solvent-based and organic solutions prior to chromatography or other instrument analyses; Excellent chemical compatibility with esters, bases, and alcohols; Biological sample preparation; High protein binding capacity: Immobilizes antigens, antibodies and other protein.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

17 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: Nylon with Glass Fiber prefilter
• Autoclavable: Yes
• Prefilter: 1 micron binderless glass fiber
• Filtration area: 1.4 cm2
• Housing diameter: 22 mm
• Membrane diameter: 17 mm
• Holdup volume: < 15 mL
• Sample volume: < 18 mL
• Maximum operating temperature 82°C (180°F)
• Maximum operating pressure: 130 psi
• Inlet/outlet: Female luer lock / Male luer slip

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
330642 has a rating of 4.9 stars based on 10 reviews.