We manufacture and distribute fine chemicals and laboratory
products - with quality and delivery you can count on every time.

Corner
Cameo<sup>®</sup> 17 mm Syringe Filter, PTFE with GF Prefilter

Cameo® 17 mm Syringe Filter, PTFE with GF Prefilter

Polytetrafluoroethylene (PTFE) membranes are naturally hydrophobic. They are ideal for filtration of strong acids and aggressive solutions, venting applications, phase separations, aerosol samplings. Chemically and biologically inert. Superior chemical resistance. Can withstand high temperatures. Improved durability and handling.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

17 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: PTFE with Glass Fiber prefilter
• Autoclavable: Yes
• Prefilter: 1.0 micron binderless glass fiber
• Filtration area: 1.4 cm2
• Housing diameter: 22 mm
• Membrane diameter: 17 mm
• Holdup volume: < 15 mL
• Sample volume: < 18 mL with prefilter
• Maximum operating temperature 82°C (180°F)
• Maximum operating pressure: 130 psi
• Inlet/outlet: Female luer lock / Male luer slip

Applications:
• HPLC sample preparation
• Dissolution testing
• Content uniformity
• Environmental samples
• Composite assays
• Food analysis
• Biofuel analysis

Image(s) are representative of the product group and not necessarily the individual product.
Catalog Item Availability Mfr. Part # List Price Unit
880-26713 17 mm Syringe filter NON sterile, FLL/MLS PP, neutral membrane, GF/PTFE, 0.22 um (50 pcs) - 50 ea

1224794 $125.85 PK
880-26734 Cameo Glass/PTFE Fiber Prefilter Syringe Filter, 0.45 um, 17 mm - 1000 ea

1229471 $1830.90 PK
880-26737 Cameo Glass/PTFE Fiber Prefilter Syringe Filter, 0.45 um, 17 mm - 50 ea

1224801 $125.85 PK
880-26740 Cameo Glass/PTFE Fiber Prefilter Syringe Filter, 0.45 um, 17 mm - 500 ea

1224803 $966.85 PK
880-26719 17 mm Syringe filter NON sterile, FLL/MLS PP, neutral membrane, GF/PTFE, 0.22 um (200 pcs) - 200 ea

1224795 $422.60 PK
880-26716 17 mm Syringe filter NON sterile, FLL/MLS PP, neutral membrane, GF/PTFE, 0.22 um (500 pcs) - 500 ea

1224796 $966.85 PK
880-26710 17 mm Syringe filter NON sterile, FLL/MLS PP, neutral membrane, GF/PTFE, 0.22 um (1000 pcs) - 1000 ea

1229469 $1830.95 PK
889-80073-PK CAMEO Syringe Filter,Glass Fiber/PTFE, 0.45 um, 17 mm dia. - 200 ea

1224802 $422.60 PK

Description Back to Top

Polytetrafluoroethylene (PTFE) membranes are naturally hydrophobic. They are ideal for filtration of strong acids and aggressive solutions, venting applications, phase separations, aerosol samplings. Chemically and biologically inert. Superior chemical resistance. Can withstand high temperatures. Improved durability and handling.

Glass Fiber (GF) prefilter is a hydrophilic material. Used also as a pre-filter to extend membrane life. Eliminate sample contamination. Excellent wet strength for each handling and filter integrity. Ideal for water/air pollution analysis, liquid clarification and cell harvesting.

17 mm CAMEO Syringe Filters provide increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Increases operating pressure up to 130 psi due to the overmold that prevents sample leaking at the seam and keeps the filter unit from bursting in half. Syringe filters are integrity-tested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging.

Specifications:
• Housing: Heat-sealed pure polypropylene without the use of glues or sealants
• Media: PTFE with Glass Fiber prefilter
• Autoclavable: Yes
• Prefilter: 1.0 micron binderless glass fiber
• Filtration area: 1.4 cm2
• Housing diameter: 22 mm
• Membrane diameter: 17 mm
• Holdup volume: < 15 mL
• Sample volume: < 18 mL with prefilter
• Maximum operating temperature 82°C (180°F)
• Maximum operating pressure: 130 psi
• Inlet/outlet: Female luer lock / Male luer slip

Applications:
• HPLC sample preparation
• Dissolution testing
• Content uniformity
• Environmental samples
• Composite assays
• Food analysis
• Biofuel analysis

Image(s) are representative of the product group and not necessarily the individual product.

Shipping Back to Top

Shipping Costs
Click here for Shipping Costs
330643 has a rating of 4.9 stars based on 10 reviews.